使用异向变分编码对临床脑部MRI进行灵活多堆栈超分辨率:尼日利亚队列中的专家读者评估
研究论文 · 2026/11/18
高分辨率脑MRI对神经放射学评估至关重要,但常规临床协议常依赖快速各向异性2D采集,尤其在资源有限环境中。这些采集在方向、对齐和解剖覆盖上可能不同,导致部分重叠的图像堆栈。现有基于学习的超分辨率方法通常依赖单一欠约束输入或固定多堆栈配置与理想采集几何。我们提出MS-HVED,一种序列无关的灵活多堆栈脑MRI超分辨率框架。可用的轴位、冠状位和矢状位堆栈被独立编码为多尺度高斯后验,并使用视野感知的高斯乘积公式融合,限制不支持区域的贡献。物理信息域随机化模拟异质临床采集条件,包括倾斜、部分覆盖和成像伪影。MS-HVED在合成基准上实现竞争性或优越的重建保真度,并改善下游组织分割相对于低分辨率输入。为评估训练队列外的泛化性,我们在尼日利亚队列的30例常规脑MRI检查上进行外部临床验证,该队列代表医学影像研究中代表性不足的人群。这些检查构成涉及44例真实病例和七位专家神经放射科医生的盲法读者研究的最大组成部分。在尼日利亚队列中,MS-HVED在210次配对评估中的187次被偏好优于监督基线,整体图像质量更高。在所有临床队列中,MS-HVED在所有可用输入下获得更高的整体质量评分(5.93 vs. 4.49,p<.001),当省略轴位或冠状位输入时偏好持续(p<.001)。代码见github.com/cai4cai/ms-hved。
该研究提出了一种灵活的多堆栈超分辨率框架,能够处理临床中常见的异质、部分重叠的MRI堆栈,并在代表性不足的尼日利亚队列中通过专家读者研究验证了其有效性,展示了在资源有限环境下的临床潜力。
High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved