CARDEA:基于空间证据的可审计推理用于端到端冠状动脉造影解读

·

研究论文 · 2026/09/11

侵入性冠状动脉造影(CAG)是诊断冠状动脉疾病的金标准,但观察者间解读差异大。现有AI系统可提高一致性,但缺乏可审计的决策过程,且全面开放式评估有限,削弱了临床信任和采用准备。我们开发了CARDEA,一个统一的大型视觉语言模型,作为CAG流程的推理核心。它仅使用公共数据集和封闭式任务进行三阶段训练:视觉特征对齐、自蒸馏的思维链框(CoB)冷启动,以及带有可验证奖励的强化学习(RLVR),其中CoB奖励鼓励在推理轨迹中使用边界框。我们评估了其两项研究级诊断:优势分类和复杂性评估,与专用分类器和两名介入心脏病专家进行比较。报告生成被排除在训练之外,并在外部队列上使用血管严重程度宏F_1进行零样本评估。CARDEA在分布内优势分类上落后于分类器,但在领域偏移下持平(准确率0.91 [95% CI, 0.86至0.95]),在复杂性评估上与心脏病专家相当(准确率0.90 [CI, 0.82至0.97])。只有RLVR改善了零样本报告生成,将其血管严重程度宏F_1(0.686 [CI, 0.664至0.707])提高到未调优基础模型(0.513)以上,并超过始终正常下限(0.312)两倍以上。CARDEA运行端到端CAG流程,从原始多视图视频到关键帧选择再到研究级诊断,同时暴露其结论背后的可审计空间证据。在可验证封闭式任务上的RLVR展现了监督模仿未能实现的开放式报告能力。临床使用需要针对专家心脏病专家进行前瞻性验证。

CARDEA通过可审计的空间证据和端到端流程,在冠状动脉造影解读中实现了与专家相当的诊断性能,并展示了强化学习在开放式报告生成中的潜力,为临床AI的可信采用提供了新思路。

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-F_1. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-F_1 (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

阅读原文

参与讨论